FAQs

Need some help? If we haven’t got your answer below, please contact us for more information.

What areas do you service in Australia?

1

Oxair Rentals can supply and service our systems anywhere in Australia.


Are systems designed to operate 24 hours day?

2

Yes Systems are designed to run continuously 24/7.


Can the oxygen purity be changed?

3

Yes by slightly closing the flow/purity control valve will increase the purity, and a corresponding adjustment in reduced flow will occur. The opposite will occur if the purity is decreased by slightly opening the valve.


Do I need a dryer to operate the Nitrogen System?

4

Unlike our competitors our systems do Not require a dryer. Our superior filtration system keeps the Infeed Air dewpoit within specification. Our larger systems have a heater to heat the Air before the membranes keeping any oil vapour in vapour state to pass with the waste gas.


Can systems be remote monitored?

5

Yes we incorporate a Starlink satellite system to monitor and make any adjustments as required.


Does the system come with all the interconnecting parts between skids?

6

Yes we supply all the interconnecting hoses using the Minsup quick connect method.


Does the Mobile system need a concrete pad?

7

Our Mobile systems can be placed anywhere as long as the ground is a reasonably stable flat surface. They are mounted inside sea containers. It is advisable to elevate the containers slightly off the ground to help protect them.



Do the Electric Compressors need a concrete pad?

8

Yes, it is highly recommended to place the electric compressors on a concrete pad. The membrane system and filtration system can be placed on a flat hard ground.

Does the system require a roof cover?

9

No, the systems are designed to be placed outdoors. The membrane system is fitted into a 20ft sea container. For its protection and ease of transport.